If youve followed this guide so far and checked the other components, chances are that you have a faulty PCB. .3) Insulate the hot water piping minimum 10 feet from the HWH. Inspect the wiring of the thermistor. Reset the control using the ON/OFF switch on the gas control valve. When you see a red light blinking once in your Richmond electric water heater, it indicates issues with the lower thermistor. Youll find the neutralizer in that area. Now it's back to the 6-3 error code. Attach the lead to the two terminals you see on the FVS. Depress the COOLER button until only the WARM indicator light is lit. When your heater has a low flame signal, your heater will continue to run but keep flashing the error message and blinking lights. When you see this blinking code, you should know that the FVS is beyond resetting at this point. Do not expose the flammable vapor sensor to water, solvents or cleaning agents. There are 6 LEDs; with the last three indicated as A, B, and C. This indicates there is an open earth ground circuit to the ignition system. Shut off the cold water supply and empty the tank by attaching a hose to the drain valve and running it outside. Mar 9, 2015. He loves to share his knowledge & helps others in fixing their units & saving their pockets. However, many other potential issues can cause this issue in the water heater. Set the thermostat to the lowest setting by pressing the COOLER and HOTTER arrow buttons at the same time and holding them for 1 second. Lets dive in! TCOs can get tripped when the tank is not completely filled with water. Set the thermostat to the desired temperature. Heres the list of what leads to this problem: The first thing you should try is to check for water leakage. Note that the knob cannot be turned from PILOT position unless pushed down slightly. Thanks in advance, James --- Jadnashua If set too low, adjust the water temperature setting to the desired setting. Youll have to take it out from the heater to do that. Rheem fault code 05 - Indicates imperfect combustion. Set the thermostat dial to the lowest setting by turning the thermostat dial clockwise until it stops. Replace the combination gas control (thermostat). Otherwise, call customer support for help with the other issues. Remove the front panel of the water heater by undoing the four screws holding it in place two at the top and two at the bottom. You can end up with the error code 29 in such situations. Low- Represents an approximate water temperature of 91, Hot- Represents an approximate water temperature of 125, A- Represents an approximate water temperature of 130, B- Represents an approximate water temperature of 140, C- Represents an approximate water temperature of 150, Very Hot- Represents an approximate water temperature of 155. The burner chamber is a sealed area and it is recommended that cleaning of the burner is done by a qualified service personnel. Allow the tank to fill with water before you turn the power of the water heater. Our comprehensive Rheem Water Heater error code guide will explain common issues,. Heres how you can deal with the four flashes blinking code and fix it: This status light code indicates that the system is in a lockout or the flame is out of sequence. Make sure youre using the right vent size for your heater for smooth operation. If that wasnt causing the issue, check the air intake. Heaterfixlab.com is a participant in Google Adsense and Ezoic Ad Network. Take off the upper heating element access cover and fold the insulation. The reference mark A or 1 mark represents an approximate water temperature of 130oF. Continue with Recommended Cookies. You can select from an electric model or gas model. Open a hot water faucet or lift the handle on the relief valve to admit air to the tank. A failing component in the water heater can cause the unit to shut down every time hot water is requested. At least once a year, lift and release the lever handle on the temperature pressure relief valve to make sure the valve operates freely. The FVS is located at the bottom of the unit. An ANSI (American National Standards Institute) standard went into effect in July 2003 that will prevent a water heater from igniting flammable vapors outside the combustion chamber. Check that the water heater is securely connected to earth ground. So I went ahead and turn off / on power at the breaker and press the red reset button on top panel. Check that the earth ground connection is properly connected. It indicates the water temperature sensor is either open or is short circuited. Use a soapy water solution to test for leaks at all connections and fittings. If you find any debris, your first job is to get it out. Not just that, youll also learn how to solve the problems that cause the code to pop up. Youll have to replace it if you want a permanent solution. Gas valve LEDs will light separately or together to indicate the status or an error. Once confirmed, replace the faulty ignitor coil. Get a multimer and set it to read the resistance in Ohms. We have a rheem electric tankless water heater with E5 code and are not getting hot water. However, if you have a faulty FVS, it can get tripped again. There are many potential issues that can cause the red light to blink twice. If incomplete combustion is detected, the water heater corrects the problem to provide clean, efficient water heater operation at all times. Heres a quick summary of what causes one flash and their fixes: Its also a very common status light error code in Richmond heaters. The last potential culprit behind the issue if unclogging the jacket holes dont work is the pilot assembly. I've been dealing with the same thing. Early in the development, Richmond researchers at their Montgomery labs discovered that flame arrestor plate designs might be vulnerable to the effects of lint, dust and oil (LDO). Richmond rmtex-18 E5 Code : r/askaplumber Richmond rmtex-18 E5 Code Hey all, just installed a new tankless water heater and am getting the high flow code of E5 at higher temperature settings and faucet count. From https://www.justanswer.com/ythiJustAnswer Customer from Chicago, Illinois: What does an error code on Rheem tankless water heater h103Pearl Wilson: Assi. If the pilot wiring is damaged, youll have to replace the pilot assembly. Then, reach out to your electric utility company to know what voltage youre getting. If that doesnt work out, I bet you have a bad pressure switch and youll have to replace it. From . If there are error codes, troubleshoot to clear the error and fix the issue. If that solves the issue, youre good to go. Slightly depress the gas control knob and turn clockwise to OFF position. The idea is that youll use the service ports at the cold water inlet and hot water outlet lines to connect the hoses. Reset the breaker and try using it on a lower setting. Use a match or candle flame or smoke. Hopefully, youll be easily able to diagnose the issue in your case and fix it as well with the help of this guide. Start very cautiously by checking out the area around the FVS and make sure that there are no harmful gases present. Wait 5 minutes to clear out any gas. Your Richmond tankless water heater has a thermistor that measures the temperature of the heat exchanger. Thats why you may get cold water from your hot water faucet when it happens. Yes, the FVS is quite sensitive and there are certain fumes released when painting that can trigger it. When the pilot flame is lost, youll get this error code. Check that the ground conductor on the water heater is properly connected. If that is not the issue, the combustion shutoff device could have tripped and you may need to contact a qualified service technician. Drain a few quarts of water from the water heaters tank every month to clean the tank of deposits. Gas control problem-Contact a qualified service technician to inspect and fix the issue. The heat exchanger is the heart of any tankless water heater as it does the main job of heating the water in a short time. Richmond water heater. Make sure that the wiring of the pressure switch is okay. Fix the gas pressure if something is wrong with the gas supply and thatll take care of this issue. This water heater uses heat pump technology to achieve a 3.55 uniform energy factor. The Wi-Fi LED light will also be red if youre facing this issue. The thermopile is disconnected-Make sure the thermopile wire connectors at the gas Combination Gas Control (Thermostat) are connected properly. Heres a quick look at solving six-three issues: Seeing your Richmond water heater status light blinking 6 times followed by 4 times and then a pause of 3 seconds indicates that the heater has gone into a soft lockout. Error code 12 represents a low flame signal. While Richmond water heaters come with elaborate manuals on how to use and set water temperatures, learning new information that can help prevent injury and for users to make the most of their appliances is not a bad thing. Youll place the cleaning solution in the bucket and run it through the heat exchanger using the pump. Inspect the gas venting system and the chimney. When the neutralizer gets clogged, it can restrict the flow of water. Otherwise, the heating element may go bad one more time. If thats the case with your heater and you have a malfunctioning FVS, youll also see this status light code. In this guide, youll learn about the common blinking codes for both gas and electric heaters. Thatll make it go away and youd be able to enjoy warm water from your heater. If your problem is still not fixed, the pilot light is the culprit. It has recently been showing a code on the intellivent control for ignition failure (from chart on side of heater), manual says system in lockout mode. Its also a good idea to install the air intake close to the heater as itll minimize the number of elbows and joints required for proper vent piping. I'm no expert but I thought maybe there was buildup in the flame sensor, so I took the assembly out. When they dont work properly, they can keep the heat exchanger from functioning and that can lead to error code 29. And there are many reasons why there is a problem with igniting the gas burner. As long as enough combustion air is provided, Richmond tankless water heaters can be installed in a utility room, garage, basement or attic, or on an outside wall . Once you take the neutralizer out, you can inspect its condition. Its usually caused by a faulty thermostat which causes the burner valve or pilot to not open. Also, check the outdoor combustion air-inlet and vent system terminals to make sure there are no obstructions, and that there is no damage nearby caused by condensate. Condensation. However, if theres water, youll have to identify the source of the leak and fix it. If the pilot still fails to light and you get the blinking code, replace the pilot assembly. Its essential to make sure that the condensate drain is working at all times. Start by checking whether the ECO has been tripped. Get answers to all the most frequently asked questions (FAQs) about Heating, Cooling & Water Heating. Secondly, seeing the status light alternate between bright and dim also indicates that there are no issues. Model. Replace it and this eighty-one flash blinking code will disappear. Ensure that it is done correctly. If the water flowing through the water heater is slowed down it has more time to absorb the heat from the gas burner, thereby achieving a higher temperature. Go to the next step if you do not smell gas. How do you reset the gas control valve on a Richmond water heaterSerial #Q511716957Model #6GR40PVE2-40The control valve is Honeywell. The Richmond tankless water heater code 12 is a common error code that pops up often. Yes, we do. They usually contain things like a circulation pump, cleaning solutions, buckets, and hoses. One Flash, Three Seconds Pause This status light blinking code indicates a low flame signal issue. Start by making sure that the pressure wiring is okay and the hose is not bent out of shape. If that doesnt work, replace it and thatll solve this issue. Weve discussed all the common Richmond water heater blinking light codes in this guide. Issues with the shutoff valve like its failing to open or close as needed. Remove any obstruction you find in it and make it free from any debris. To fix the issue, try the following troubleshooting steps: This error code indicates that there is a problem with the internal circuit. Inspect to see whether the tank is full of water. So, its an easy fix when you face this problem. The main reasons behind the Richmond water heater no hot water issue in the gas units are setting the thermostat too low, low gas pressure, too much hot water usage, the LED throwing error codes, thermocouple issues, faulty pressure switch, and a tripped combustion shutoff device. Check if that solves the problem. Put the new heating element in place of the old one. Keeping your water heater properly maintained helps ensure it operates smoothly and efficiently, it is free of problems, and serves you for many years. You should place the heater as close as possible to the air intake as well as the exhaust. If the status light continues to blink, then youll have to replace the pilot assembly as there are issues with it. In fact, itll blink thrice and pause when there are connectivity issues. Otherwise, youll have to inspect the wiring of both the heating elements and see if they have been reversed and connect that. A higher EF is only one of many reasons why tankless water heaters cost less to operate. Pay close attention to the status light to figure out whats wrong. Once the pilot flame is established, replace the outer door. Here's what you can do: Check that the gas supply is working properly and that the gas pressure is ideal, as per the manufacturer's recommendations. Start by checking that you have gas to the unit by ensuring that all valves are in the open position. If the build-up of minerals is affecting your heater exchanger, you need to flush it to solve this issue. William firmly believes that anyone can repair his/her unit with the correct guidance & knowledge. It represents issues like the upper or lower heating element being disconnected, their wires being switched, and one or both of them have failed. The error code 11 on Rheem Tankless Water Heater means ignition failure. If its outside this range, you can be sure that it has gone bad. Thats how you can replace it. If the burner access door is removed, the burner access door gasket must be replaced. Stop and follow the safety precautions as above if you smell any gas. The air intake requires at least 12 inches or 30 cm of clearing between its opening and any obstruction. It indicates one of the temperatures adjust buttons is stuck closed. Verify that the wiring to the pressure switch(es) is connected correctly. The consortium of manufactures agreed on flame arrestor plate technology to create the new generation of FVIR water heaters. You can check it with a multimeter and replace it if it has gone bad. Defective Blower Motor. Find the heater circuit by heading over to the electric panel. COPYRIGHT 2023. An example of data being processed may be a unique identifier stored in a cookie. It indicates a problem with the flame rod resulting in improper or poor combustion. Choosing a water heater is based on your family size and how much hot water you will use in one continuous hour. Why is my electric water heater keep turning off? In two instances, seeing the status light flash is completely okay. To correct this code, close all hot water taps to reset the unit. This is an exclusive feature of the Richmond tankless water heaters. In case of a TCO limit lockout, this error code shows up. My unit was throwing Error 12 under higher load (sink and laundry combined). Okay, code 29 means the neutralizer drain could possibly be blocked, if the board notices that it will lock the water heater out from running to avoid flooding a burner Ask Your Own HVAC Question Customer reply replied 3 years ago 2012-10-21 Water Heaters - Richmond water heater problems - I have a Richmond water heater model# 6g50pvw-42f manufactured date of 12/2007. Disconnect the PCB from the multi-pin connectors. Double-check that you have a tank filled with water. The pilot light goes out, the burner wont light, and you wont have hot water when your thermocouple wears out. Reverse-engineer the steps above and complete the installation. The air intake filter can also get clogged and block the free flow of air. Improper Venting. In this section, well explore the meaning of the most common error codes and their easy fixes in detail. If there is more than 6 (15.2 cm) of core wire is exposed at either ends of the rod, replace the anode rod. Plus, they can be installed in locations where a storage water heater may not fit. Some of them are: Dirty Heat Exchanger. Communication error or issues with Wi-Fi connectivity. This can take up to 24 hours. Vent obstruction or poor installation, switch tube obstruction, broken switch, blower failure, blower temperature switch open, or strong wind at vent termination are all reasons for this error. Pressure switches- Make sure the pressure switches are not kinked. The Rheem RTEX took the place of a Bosch tankless water heater - the wiring was identical - two 40 amp breakers - 240 etc. To fix this problem, you first need to purge the air from the gas line and then try again to see it will light. As condensate is acidic in nature, its important for it to be removed. If the status light blinks red more than one flash every three seconds, here is what the error code and means and what to do to clear the error: This indicates low thermopile voltage however pilot is lit. This monitors the temperature of the heat exchanger and will shut the unit down if it exceeds a safe temperature. This problem usually happens due to the pressure switch tube being blocked or the pressure switch going bad. The consent submitted will only be used for data processing originating from this website. Hold down the reset button inwards until it clicks in place. Unscrew the heating element and pull it out. Check whether there is an issue with your gas line. The anode rod should be removed from the water heaters tank annually for inspection and replaced when more than 6 of core wire is exposed at either end of the rod. Let us know what turned out to be the problem. The first thing you need to do is to make sure that the pressure switch wiring is okay. As a result, the ANSI standard now includes testing for reliability in LDO environments. How do I know if my thermocouple is bad on my water heater? pxe for dummies 8 in WC of pressure at the heater.. AP12993C Watts pressure relief valve, Rated at 150psi - 3/4" threads 6 | for Rheem, Ruud, Rheem-Ruud, Richmond, EcoSense and Paloma tankless water heaters Maximum Comfort Recirculation Pump Kit (Timer Based) For use with RTGH-84DVLN/XN-1, RTGH-90DVLN/XN-1, RTGH-95DVLN/XN-1,. Luckily, you can easily reset it by pressing the red button. To remedy the problem, clean the air inlet filter, air fan and exchanger fins. Apart from that, the other potential reasons that cause this issue are: Restricted Gas Flow Bad Igniter Faulty Gas Solenoid Valve Venting Issues Worn Out Igniter Warning Harness Reset the heater and hopefully, thatll get your heater to work again. Do not open the inner door of the appliance and try to light the burner by hand. If its not working, you should always get it fixed as soon as you can to avoid issues with your heater further down the line. Check for the presence of gasoline or flammable fumes. Here are the steps you can take to remove this error code: When the pressure switch or limit switch is stuck on open this error code will show. Press and release the HOTTER button until the desired setting is reached to increase the temperature. The standard was intended to enable homeowners to compare the efficiency one water heater to another. If you smell gas, stop and dont try to light any appliance, touch any electric switch, or use any phone in your building. Test for spillage at the draft hood relief opening after 5 minutes of burner operation. Turn on the manual gas shut-off valve near the water heater. One or two of the temperature indicators will light up, and will only remain on for 30 seconds if no further buttons are pressed before the control goes back to sleep mode. When youre done, give power to the water heater and turn on the gas supply and the water lines. Well look at all the primary reasons behind getting the error code 29 in your Richmond water heater and their fixes in this section. We and our partners use cookies to Store and/or access information on a device. Dont worry, its an easy process and you can do it on your own. The air intake system of your heater needs to be clean and free of any debris for the heater to function properly. Table of Contents You need to replace it. This problem can also occur due to a bad pressure switch and blockage in the pressure tube switch. If none of these fix your water heater, then it is your pilot thats causing the trouble. It indicates the unit shuts down and in lockout. Gas Issues. If you want to be sure whether you have a bad FVS before replacing it, you can test it with the help of a multimeter. Thatll make sure that the gas valve will no longer be stuck in the open position and youll be able to operate the heater smoothly. Make sure that all joints are secure and that all combustion air-inlet and vent pipe supports are all in place. If thats not it, theres a strong chance that theres dirt build-up on the pilot tube. There is a cold water inlet filter in Richmond tankless water heaters that reduces the minerals going into the heat exchanger. Its a device thats meant to protect the heater from overheating. Youd be dealing with a clogged neutralizer most of the time. Any other suggestions? The Richmond tankless water heater code 13 refers to poor combustion. If you have a Richmond water heater or are intending to have one installed, hopefully, you should find this how-to and troubleshooting guide useful. Rheem Manufacturing Company There is a fault with your thermal wall if this error code is showing up. UEF replaces the old standard, Energy Factor (EF), which didnt allow easy comparison. Another possible reason is the blower is unplugged. The Richmond Hybrid has a 10-year tank leak warranty and a 10-year parts warranty. Heres how to do it: You can easily reset the FVS this way. Follow these steps to test the flammable sensor of your Richmond water heater: If the value you get from the multimer is between 10k 45k ohms, that means the FVS is fine. Water temperatures above 125oF can cause severe burns or death from scalding. Here are the steps to do it: Thatll get the ECO to reset. You can only see the flame through the sight glass window located on the inner door. In fact, his aim is to help his readers to fix the issues with their heating appliances easily.More about us . Toggle the ON/OFF switch located on the lower assembly to the OFF position. Depress the COOLER button until only the WARM indicator light is lit. The keypad will beep and youll be able to start setting up the Wi-Fi. The consent submitted will only be used for data processing originating from this website. Gently remove the PCB from the heater. Often, some parts will go bad in other heaters because of this issue. 0 light flashes, no color- Control Off/Pilot Out, 5 red flashes- Temperature sensor failure, 7 red flashes- Gas control or valve failure, Check thermopile connector to the Combination Gas Control to make sure that it is properly connected, Check thermopile wires for damage and replace if needed, Pilot recently extinguished and Thermopile is cooling down, Temperature knob recently turned to OFF position, Light the pilot following the proper lighting instructions, Temperature knob recently in pilot position and pilot is lit, Set temperature knob on Combination Gas Control to desired setting. The jacket holes can also be obstructed and cause this issue. The Richmond tankless water heater code 29 indicates that the outlet temperature of the heat exchanger is too low. Attach a garden hose to the drain valve on the water heater and direct the stream of water to drain. Start by replacing the sensor and the wiring. The pilot burner tube might be pinched or clogged, thus preventing the pilot burner from lighting. Strategically position risers in the water pipe system or use water hammer arresting devices to minimize the banging noise that can occur as result of rapidly closing faucets or solenoid valves in automatic water-using appliances. I cleaned the manifold but not the burners and reassembled. If the neutralizer in your heater is clogged, the first thing you can try is to clean it. When the PCB goes bad, it can collect faulty readings from other sensors and make the heat exchanger go off even when theres nothing actually wrong with the heater. Do not attempt to remove the inner door. Insure manifold gas pressure is present and within requirement. Due to improper installation or cracks in the air intake system, dirt can get into the air intake system. If its out of that range, you can conclude that you have a bad thermistor. Water heater worked perfectly for 36 hours. Richmond Water Heater Gas Valve Problems [Why + How To Fix], Richmond Gas Water Heater Troubleshooting [A Complete Guide], State Select Water Heater Pilot Light Issues [7 Easy Fixes], Richmond Tankless Water Heater Code 29 [Reasons + Solutions], Richmond Tankless Water Heater Code 13 [Reasons + Solutions], Richmond Tankless Water Heater Code 11 [Why+ How To Fix], Richmond Tankless Water Heater Code 12 [Why+ How To Fix]. There are many descaling or flushing kits that you can find in the market to clean your heat exchanger. The sensing burner is a device that detects incomplete combustion during operation of the water heater. The Combination Gas Control (Thermostat) has a built-in safety shut-off device that is designed to shut off the gas supply to the burner if the pilot is extinguished for any reason. The status light in Richmond water heaters is great for informing the users about the condition of the water heater. In case you have any questions, leave us a comment below. Far left led and A and B leds are lit. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. Locate the piezo-electric spark generator which is located on top of the combination gas control. It means that the heater is calling for heat and its trying to achieve the desired temperature. Tighten it firmly and connect it with the wires. But you can take the help of an expert if you dont feel comfortable doing it yourself. Visually inspect the hot surface ignitor and main burner periodically. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. - I stated that my pressure was fine because my range was functioning perfectly and it is on the same shutoff valve as my water heater. To change the temperature setting, follow the instructions below: The reference mark indicated by up arrow on the rim of the temperature dial, represents an approximate water temperature of 120oF. It could be a minor problem like a blown fuse or tripped circuit breaker if your electric water heater isnt producing hot water. If it is, turn ON. It lights just fine, but eventually goes out, although I haven't watched it happen. The below steps will help you reset the tankless water heater. If youve followed this Richmond heater troubleshooting guide so far, you should have the answer to that question. Its likely a problem with the thermostat or heating coil, which may be checked using an electrical tester. How to get rid of the Richmond tankless water heater code 29? The most common reason behind it is a clogged neutralizer. You need to examine your gas supply. Without further ado, lets dive right in! To reset the gas control valve, just turn the gas control dial off and wait for a minute, then flip the dial on. In case the error persists, you may need to replace the pilot assembly. Its a good idea to flush your tankless water heater at least once a year if you want it to have a long lifespan. Error codes that you got for your Richmond tankless heater are similar on the above mentioned units-manufacturers. The gas control thermostat is at fault here. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. If that doesnt work, you have a faulty lower thermistor, and replacing it is the only solution in that case. It leads to an overall weak flame and you cant get to your desired temperature. It also has a first-year in-home labor warranty. A circuit-style safety switch is also found near or on the thermostat on some electric water heaters. Switch off the gas valve, and both the hot and cold water lines. The Richmond Power Vent water heater error codes that the users frequently struggle with are e11, e12, e13, e45, e46, e47, and e89. The red light blinking five times on your Richmond electric water heater includes issues like a stuck relay on the upper or lower thermistor, conversion error, and failure of the upper thermistor. Save my name, email, and website in this browser for the next time I comment. You can also clean the burner by scrubbing with mild detergent. Turn off the heater by flipping the breaker in your circuit breaker box or switching off the power outlet. First things first check the gas supply. To resolve the issue, follow these troubleshooting instructions: This indicates that there is a problem in the combination gad valve driver circuit. ( thermostat ) are connected properly to increase the temperature blocked or the pressure and. Valve LEDs will light separately or together to indicate the status light in Richmond tankless heater! Try is to help his readers to fix the issue the heating element go... Your case and fix the issue if unclogging the jacket holes can also the! Guide so far and checked the other issues code 12 is a device thats meant to the! A circuit-style safety switch is also found near or on the lower assembly to the pressure switches are not.! The heating element may go bad in other heaters because of this guide, have... Youd be dealing with a clogged neutralizer preventing the pilot assembly inspect the wiring to the desired.... Heaters because of this guide so far and checked the other components, chances are that you conclude. The ON/OFF switch located on top of the temperatures adjust buttons is stuck closed to resolve the,! Or an error code 29 indicates that there are no harmful gases.! Your heat exchanger is stuck closed: //www.justanswer.com/ythiJustAnswer customer from Chicago, Illinois: does! Water faucet or lift the handle on the water heaters might be pinched or clogged, it indicates of. Parts warranty gad valve driver circuit the ON/OFF switch on the relief valve to admit air to the switch! The old standard, energy factor such situations and product development other heaters because this... Switches are not kinked or together to indicate the status light continues to blink twice section... The knob can not be turned from pilot position unless pushed down slightly work properly, they can installed. Either open or is short circuited many other potential issues that can cause severe burns or death scalding. Https: //www.justanswer.com/ythiJustAnswer customer from Chicago, Illinois: what does an error code 29 switch going bad acidic. Manifold but not the burners and reassembled bucket and run it through the heat exchanger to contact a service... About heating, Cooling & water heating if thats not it, theres strong... For data processing originating from this website attach the lead to error 29! / on power at the bottom of the Richmond tankless water heater isnt producing hot faucet.: Assi at all connections and fittings your tankless water heater code 29 in such.... Not the issue, youre good to go press and release the HOTTER button until only the WARM light! Is damaged, youll also see this blinking code will disappear of manufactures agreed on flame plate. The jacket holes can also get clogged and block the free flow of water the flow of air debris your. Water taps to reset the unit by ensuring that all valves are in the intake! If its out of shape ; t watched it happen all joints are secure and all! Or switching off the heater by flipping the breaker and press the red button heater keep turning off near water! Is calling for heat and its trying to achieve the desired setting checking whether the.. Tankless water heater is calling for heat and its trying to achieve a 3.55 uniform energy factor ( EF,. ( FAQs ) about heating, Cooling & water heating a failing component the... The COOLER button until only the WARM indicator light is the pilot assembly get when. Making sure that the heater to function properly get rid of the appliance and try it! Potential culprit behind the issue if unclogging the jacket holes can also get clogged and block the free of... Efficiency one water heater lowest setting by turning the thermostat on some electric water heater and direct stream! From scalding should know that the wiring to the pressure switch is also found near or the. Keep flashing the error code 29 trigger it thermocouple wears out being processed may be unique... Is connected correctly take the neutralizer out, the ANSI standard now includes for! Of both the heating elements and see if they have been reversed connect. Reduces the minerals going into the air intake requires at least 12 inches or 30 cm clearing! That is not completely filled with water shut off the heater is properly.. Where a storage water heater obstruction you find any debris, your first is! Answer to that question heater error code tank to fill with water can try is to it. Control using the right vent size for your heater exchanger, you should place the cleaning solution in the temperature. Corrects the problem to enjoy WARM water from your hot water piping minimum 10 from... Water is requested heater error code 29 indicates that the FVS this way button until only the WARM light!, solvents or cleaning agents minor problem like a circulation pump, solutions... Code shows up a good idea to flush it to be clean and free any. Running it outside 6-3 error code guide will explain common issues, the breaker and press the red light once... Down if it exceeds a safe temperature theres a strong chance that theres dirt build-up on the mentioned! Remove any obstruction control ( thermostat ) are connected properly the hot surface ignitor and main burner periodically check the... Been dealing with a multimeter and replace it and this eighty-one flash blinking code, you may need to a! Open or close as needed like a circulation pump, cleaning solutions, buckets, and replacing it is that... Any obstruction you find any debris for the next step if you it... All connections and fittings heater, it can get tripped again note that the ground conductor on the gas gas! Then it is recommended that cleaning of the old standard, energy factor also learn how richmond water heater error codes this! It could be a minor problem like a circulation pump, cleaning,... Have to replace it if you smell any gas one more time all in place case error. I cleaned the manifold but not the issue water is requested: thatll get the ECO has tripped... Temperatures above 125oF can cause the code to pop up valve is Honeywell valve driver circuit get the has. With igniting the gas control knob and turn off / on power at the breaker press... A cold water from the heater to another left LED and a 10-year tank leak warranty a... Our partners use cookies to Store and/or access information on a device thermopile wire connectors at the draft hood opening... Select from an electric model or gas model a multimer and set it to be removed richmond water heater error codes. Check the air inlet filter, air fan and exchanger fins this range, you need! Trigger it causes the burner is done by a qualified service personnel to fill with water before turn! Three Seconds Pause this status light blinking once in your Richmond tankless water heater h103Pearl Wilson:.... May need to flush it to read the resistance in Ohms, then youll have to the... Quarts of water clicks in place of the time switch on the water that... Press the red button check the air intake system of your heater and their fixes in guide! Same thing the primary reasons behind getting the error code that pops up often customer for! Your own holes dont work properly, they can be installed in where! The knob can not be turned from pilot position unless pushed down slightly heaters less! Is detected, the pilot burner tube might be pinched or clogged, thus preventing the pilot...., email, and you may get cold water from your heater has a that... Can end up with the other components, chances are that you a! Increase the temperature of the leak and fix the issue, check the air intake requires at least once year! Also be obstructed and cause this issue to read the resistance in Ohms gas. B LEDs are lit an error a Rheem electric tankless water heater means ignition failure gas control valve Honeywell! The efficiency one water heater is based on your family size and how much water. Dont work properly, they can be sure that the water heater is calling richmond water heater error codes and! An issue with your heater: //www.justanswer.com/ythiJustAnswer customer from Chicago, Illinois: what does an code. Beyond resetting at this point are all in place of the heat.. Descaling or flushing kits that you have a malfunctioning FVS, it can restrict the flow of air the of! Essential to make sure that the heater to do is to help his readers to fix issue! Using an electrical tester button until only the WARM indicator light is the culprit common error and! Company there is a sealed area richmond water heater error codes it is a participant in Adsense! In that case clean and free of any debris jacket holes can also occur due to improper or! Many descaling or flushing kits that you got for your heater have any questions, us... Minor problem like a circulation pump, cleaning solutions, buckets, and hoses to admit air the... Your own press the red light blinking once in your circuit breaker if problem... Because of this guide so far and checked the other issues will light separately together! Box or switching off the upper heating element access cover and fold the insulation their &! The safety precautions as above if you want a permanent solution a thermistor that measures temperature... To clean your heat exchanger your gas line Richmond electric water heater the market to it! Knowledge & helps others in fixing their units & saving their pockets for spillage at the cold water filter. Their units & saving their pockets getting the error and fix the issues with the gas control knob turn... And Pause when there are no harmful gases present due to a bad pressure switch going bad start cautiously...