Fireplacehubs.com is a participant in the Amazon Associates Program, Google Adsense, and Ezoic Ad Network. Using an open-end wrench, unscrew the nut that holds the thermocouple end fitting into the gas control valve. Honeywell, White Rodgers, and other manufacturers make universal replacement thermocouples, usually with a 30-millivolts (mV) rating for standing-pilot furnaces. Insert the new thermocouple from the outside through the grommet or opening in the burner assembly manifold cover. Fire Sense has the policy to address customers' ever-changing heating needs, and that's why you'll find their fireplaces offer extraordinary quality, exceptional performance, and a wide range of solutions to heating problems. A thermocouple works to produce a small electrical voltage output by connecting two dissimilar metals or two wires forming a measurement junction at the sensor tip of the device. Turn off the gas supply to the gas valve. HSS-A-GH, GS4400BK, GS4400GD, GS4400SS, ALSO FITS FIRE . Use a small tooth file to remove the carbon buildup from the thermocouple. The only tool you need to replace a thermocouple is a wrench. Fire Sense LPG Patio Heater Thermocouple Replacement Fire Sense 268 subscribers Subscribe 28K views 10 years ago For more information regarding this Fire Sense product please visit. Flame sensors and thermocouples are simple parts that wear out and fail over time, and most are easy to replace. Read our, How to Replace an Electronic Flame Sensor, How to Replace a Water Heater Thermocouple or Flame Sensor, How to Light the Standing Pilot Light on a Gas Furnace, How to Check a Pilot Light on a Gas Furnace, A Visual Guide to a High-Efficiency Condensing Furnaces, How to Clean a Gas Fireplace the Right Way, How to Replace a Mobile Home Water Heater, 8 Common Problems With Conventional Gas Furnaces, How to Turn on a Gas Fireplace With a Wall Key, How a Furnace-Mounted Home Humidifier Works, 6 Common Reasons Your Gas Water Heater May Not Be Working. Manufactured from UL-approved Nylon 66, 94V-2. Pull off the complete thermocouple setup after that. The thermocouple is a thermally sensitive device that communicates with the gas valve via a modest electrical pulse. Empty or not having enough gas in the propane tank is another caveat behind this issue. There are numerous styles to choose from. For thermocouples working correctly, your reading should range between 25-30 millimeters. Bob Formisano is a licensed architect and builder with nearly 40 years of experience building new homes and restoring older homes. Hiland Thermocouple $24.00 $18.99. The thermocouple senses the gas pilot flame and prevents flow to the main burners when there is inadequate heat to ignite the burner. Then, use steel wool to clean the thermocouple by removing dirt & dust. Thirdly, use the pliers to remove the valve. $9.75. Choose something compatible with your thermocouple. Replace the probe in the clip and place it at a safe place from the pilot flame. To turn off the gas to the furnace, use the valve handle located on the gas pipe running into the furnace. However, it is recommended that you check your thermocouple prior to replacing it. If you are not inclined, hire a professional technician to clean the orifice for you. Otherwise, you should replace the gas hose & regulator assembly if the gas is on but there is no gas flow. Read on to find out. . Have Customer Service contact you. If your furnace pilot light won't stay lit, then it might be an easy fix.In this episode of Repair and Replace, Vance shows how to replace the thermocouple i. Pilot Assembly The pilot assembly's job is to keep the patio heater lit. Place one lead on one of its sides. If the pilot flame goes out, the tip cools and the thermocouple automatically shuts off the furnace's gas valve. Choose the new thermocouple based on the size and mounting style of the old one. Its installed on top of your gas furnace. Turn on the gas and electrical power to the furnace. If you receive a reading of less than 25 or none at all, your thermocouple has to be replaced. Save my name, email, and website in this browser for the next time I comment. Install a New Thermocouple. Reinstall the rest of the water heater's components. Fixing those heater issues will help to let your patio heater function again to bring back the warm environment on your patio. Next, ensure there is enough fuel in the propane tank. Patio Heater Fire Sense FireSense PH08-S Owner's Manual. To disconnect the connector, use a wrench tool. Replacement Parts Thermocoupler and FD Product Description & Features: Anti Tilt Switch with Thermocouple wire : Gas heaters Outdoor heaters Gold plated connectors inside. $469.00. Fire Sense heats are made with appearance and durability in mind by only using some of the top materials you can buy. Expert help is available online, over the phone or in person at one of the many locations across Canada.Connect with AMRE SupplyWebsite - https://www.amresupply.com/Facebook - https://www.facebook.com/amresupplyTwitter - https://twitter.com/amresupplyInstagram - https://www.instagram.com/amresupply A backyard is always incomplete without the classy outdoor furniture, and when its the matter about outdoor living space, choosing a durable patio furniture sets is not an easy task.Shop for Fire Sense, Patio Sense, and more at TheOutdoorStore.co!https://www.theoutdoorstore.co/fire-sense-products/ Installation other than as instructed by Heat-N-Glo. Toll free: 866-985-7877 A clogged gas valve orifice is responsible for not turning the patio heater on. If the thermocouple is defective, you should replace it with a new one. Both are safety devices that sense the presence of a flame and control the flow of gas to the appliance accordingly. To warm the thermocouple probe, keep the valve under watch. Toll free: 866-985-7877 The stove still runs fine, but the end of the Thermocouple has the beading protection missing from it that should be on it. 2 connectors for attaching to an anti-tilt device. William is the founder of Fireplacehubs.com. | Free standard shipping. New Fire Sense 46,000 BTU Ash and Stainless Steel Gas Patio Heater. Check to see if the flame stays bright after lighting the pilot. Shop products from small business brands sold in Amazons store. With a probe, install the new thermocouple. 5" Gas Thermocouple, Temperature Sensor Flame Failure Safety Device, Replaces Robertshaw 446-511, Compatible with Direct Vent Fireplace, Heat & Glo & Hearth (700mm, M11x1, M10x1) Universal Gas Thermocouple Kit, 600 mm. Remove the furnace's access cover. Fire Sense 1,500-Watt Stainless Steel Infrared Electric Patio Heater. How to Replace a Thermocouple Open the Access Cover Remove the furnace's access cover. Fire Sense 61966 Clip Mount Thermocouple High Standard Solid Copper & Brass Material with High Temperature Resistant Protection Sleeve, Fire Sense 62152 Flame Heater Replacement Thermocouple High Standard Solid Copper & Brass Material Fits with Flame Heater Models 60804, 60523, 61220 & 61221. The patio is a place for fun, relaxation and dining. How to install replace a thermocouple in a hot water heater DO IT YOURSELF ITS EASY 7.7K views 2 years ago Mr. Heater won't light (repaired) and how to bypass a thermocouple part 1 of 2. Castle Rock Heating And Air is the ideal option if you need skilled, Signs Its Time To Hire A Professional Fireplace Repair Services. This study proposes the experimental evaluation of alternative refrigerants with low global warming potentials (GWPs) such as R1234ze(E), R513A, and the mixture R516A as a drop-in replacement for R134a in a domestic refrigerator with a volumetric capacity of 513 L. Initially, the optimal charge for each refrigerant was defined based on the minimum energy consumption of the refrigerator, then . On the other hand, you should purge the gas line if there is air in it. Fire Pit Parts. We offer all the electric, natural gas and propane heater parts and accessories you need. Besides, the air in the gas line causes the patio heater to not light up. Thermocouple for patio heaters model numbers 2210, 62211, 61718 and 61710. Disconnect the electrical wire leads to the sensor. Patio Heater 46,000 BTU Commercial Grade 304 Stainless Steel Frame with rich brushed finish Lifetime defective parts replacement warranty . Each of your file(s) can be up to 20MB in size. Choose something compatible with your thermocouple. $ 21.99 availability: In Stock Quantity + - Add to Cart Product Details: To assure best replacement, compare your current thermocouple to the photo. The thermocouple connection at the gas valve should have no thread sealer paste or thread tape at the retaining nut. In many cases, it is easy to pull out the single burner that holds the pilot assembly. 3. If you need a part in a hurry, find a local dealer who has the part in stock. Therefore, your Fire Sense Patio Heater wont stay lit if the gas valve is off or the igniter gets worn out. If your furnace pilot light won't stay lit, then it might be an easy fix.In this episode of Repair and Replace, Vance shows how to replace the thermocouple in a standing pilot furnace. If its empty, get your propane tank to your nearby gas station and refill it. Some models will use hex nuts while others will simply install screws. When the handle is perpendicular to the pipe, rather than parallel, the gas is off. Amazon.com: Fire Sense Replacement Parts 1-48 of 207 results for "fire sense replacement parts" Fire Sense 61437 One Piece Round Heavy Duty Premium Reflector Upgrade For Gas Patio Heater With 3 Barrel Bolt Design Fits Any Of Our Gas Patio Heaters - 38" Diameter 4.3 (87) $16003$249.99 FREE delivery Tue, Apr 11 Only 8 left in stock - order soon. Patio Heater Fire Sense Deluxe Patio Heater Pilot Assembly Replacement (9 pages) Patio Heater Fire Sense 28inch Round Fire Pit Instructions Manual. If there's a problem with ignition and the burners fail to light or go out, the flame sensor is designed to shut off the gas to the burners. Maybe The Gas Valve Is Off Or The Tank Is Empty, 4. The length you see listed on the package (such as 24 or 30 inches) is the length of the thermocouple's lead, which is the flexible metal wire between the fitting end that attaches to the gas valve and the thermocouple tip that sits in the pilot flame inside the furnace. Remove the furnace's access cover. Carbon build-up on the thermocouple or low gas pressure will prevent your patio heater from lighting up. Fire Sense PH01-S Instruction Manual & Parts List Patio Heater Model: PH01-S PH01-SS Item numbers: 02411,02412, 60755, 60786, 60788 WARNING: For outdoor use only. Turns out, sanding the thermocouple gently will also help to remove the coat of carbon. Since the thermocouple is connected to the gas valve via this connector. High density quartz glass. Disconnect the probe from the clamp. How do you bypass a thermocouple? Low Pressure LPG Propane Gas Fireplace Fire Pit Flame Failure Safety Control Valve Kit with Thermocouple and Knob Switch, 3/8" Flare Inlet & Outlet, Fits for Gas Grill, Heater, Fire Pit, Fireplace, BALI OUTDOORS Gas Fire Pit Propane Fire Column, 23 Inch Cylinder Firepit, 50,000BTU Round Fire pits, Patio Fire Place W/ 22lb Blue Fire Glass, Black, MCAMPAS 5/8"-18 UNF (3/8" Swivel Flare) Male Flare Gas Safety Control Valve Thermocouple Assembly Kit for Low Pressure Propane Fire Pit, Fireplace, Resideo CQ100A1047 48-Inch Replacement Thermocouple for Gas Furnaces, Boilers and Water Heaters, Hiland NG-GT-BRZ Natural Gas Commercial Glass Tube Patio Heater w/Wheels, 42,000 BTU, Variable Heat Control, Pyrmaid, Bronze, MENSI Propane Gas Fireplaces Fire Pits DIY Safety Replacement Part Pilot Burner Assembly For Propane Igniter Kit M8x1 Thermocoupler with OD 4mm Copper Tube Connection, Endurance Pro 60125501 Thermopile, Millivolt, Power Generator, AF, 250-750 MV Compatible with Pitco, Southbend and Anets Gas Fireplace, Water Heaters, Gas Fryer Cluster for 24 inch Fireplace, Skyflame 19" Round Stainless Steel Fire Pit Drop-in Burner Kit with CSA Certified, Flame Sensing, Electronic Spark Ignition, Propane Regulator Connector Hose Set for Propane Tank, Aupoko Patio Heater Thermocouple, Outdoor Heater Replacement Parts M8 x 1 End Connection Nuts Thermocouple 410 mm Length M6 x 0.75 Head Thread with 6.3 MM/0.25'' Flat Terminal, Propane BBQ Grill, Firepit, Fireplace Heater Universal Gas Thermocoupler Sensor M8x1 Thread,Length 600mm/24inch, CALPALMY New Propane Gas Patio Heater Repair Replacement Parts Thermocoupler & Dump Switch Control Safety Kit - 1-Pack, Game Pawn Bonanza Variety Pack - 500 Plastic Multicolored Bulk Gaming Pieces - Fantasy Tabletop Strategy Game Accessories, Markers, & Upgrades - Learning Resources, Counting Aids, Toys, Arts & Crafts, Universal Gas Thermocouple 24" Length Used on BBQ Grill or Fire Pit Heater or Gas Water Heater M8x1 End Nut and Head Tip, PAMAPIC Patio Heater Glass Tube Replacement for 4-Sided Outdoot Patio Pyramid Heater49.5 inch tall, Select from High Quality Thermocouple Probes, All customers get FREE Shipping on orders over $25 shipped by Amazon. Step 4: With a probe, install the new thermocouple. We receive monetary benefits in return for showing ADs on this website and by linking to Amazon and affiliate sites at no cost to you. Tall Patio Heaters. Vernon AE & Edge 60 Thermocouple K + Protection Tube Bundle - $29.00. Put the pilots assistant light on. The gas valve is attached to the pilot aperture via this metallic copper tubing. . Details Select delivery location In Stock Qty: 1 Buy Now Payment Whenever the pilot is on, it transmits an electric signal that maintains the gas valve open. If you get the readout below this, understand the thermocouple is defective. To assure best replacement, compare your current thermocouple to the photo. Step 3: Take the thermocouple you removed to the repair shop. Cannot turn the Configure the meter to measure in millivolts. 2. Thread the end fitting of the thermocouple into the gas control valve and tighten it by hand. Why Will My Propane Patio Heater Not Light? When patio heaters fail to turn on, often it is an issue with the thermocouple which is causing the pilot to be weak or not work at all. Step 3: Take the thermocouple you removed to the repair shop. He specializes in estimating as well as design and engineering for plumbing systems, and he works for one of New York's largest union plumbing construction companies. Hours: 9:00am 6:00pm EST, Click "Write a Review" for a bonus YEAR of warranty coverage! It may be easy to pull out the single burner that holds the pilot assembly. Discover more about the small businesses partnering with Amazon and Amazons commitment to empowering them. Then, use an 8mm wrench to remove the thermocouple from the heater. . A thermocouple consists of a metal gas tube (usually made of copper), a probe that extends into the pilot flame, a bracket, and a wire that leads to the gas control unit. Emergency Management and Communication. Locate where the thermocouple is fastened to the standing pilot burner assembly bracketthere should beeither a nut at the bottom of the bracket or two nuts, one below and oneabove the bracket. To assure best replacement, compare your current thermocouple to the photo. Features. Fire Sense 61964 Threaded Thermocouple Female Spade Connector Brass Fitting Flame-Out Protection Fits with Most of Propane Patio Heaters - 62224 & 61116. The most common symptom of a bad flame sensor is a furnace that cycles on and off repeatedly every few seconds. Pull off the complete thermocouple setup after that. (Advice), Noritz Tankless Water Heater Code 16 [Why + How To Fix], Noritz Tankless Water Heater No Water Flow [Reasons + Fixes], Noritz Tankless Hot Water Heater Codes 11 And 12 [Why + How To Fix], Bradford White Water Heater No Status Light [Why+ How To Fix], Noritz Tankless Water Heater Code 14 [Reasons+Solutions]. Fire Sense is the leading brand name in outdoor heating and electric fireplaces. HSS-A-GH, GS4400BK, GS4400GD, GS4400SS, ALSO FITS FIRE SENSE PATIO HEATERS. We offer Fire Sense products in both LP and Natural gas and a varity of finishes. Your Fire Sense patio heater wont light if the carbon build-up forms on and around the thermocouple. End Connection:M8X1 ; Probe Size: 6. Like a thermocouple, the flame sensor has a metal probe and bracket, but it has no gas tube. Empty propane tanks, blocked or defective gas hoses & regulators are also responsible for low gas pressure. Take a hex nut driver or screwdriver and loosen the objects holding the two thermocouple wires in place. Established in 1998, as one of the brands of the Well Traveled Living product family, the Fire Sense product range consists of gas and electric patio heaters, fire pits, patio fireplaces, patio torches and electric fireplaces. City of Chicago Utilities. A thermocouple is typically found in older furnaces, whereas new installations are now required to use electronic ignition furnaces, which use less energy since there is no pilot that burns gas constantly. Find thermocouples, knobs, wires, and tubes from our shopping cart. For an electronic ignition unit, you would have to remove and then reinstall the igniter. The Fire Sense Patio Heater has a spark igniter. The thermocouple usually lasts for ten years. Glass tube replacement for tabletop glass heaters. If the thermocouple is bad, the furnace usually refuses to ignite (since the pilot light no longer burns). Confirm that the flame sensor is removableif so, it should be fastened to the burner assembly with one or morescrews. Current Stock: 5. Since a disconnected The M-series sensor has a built in thermocouple that accurately measures the temperature of the gas flame, allowing you to keep an eye on things and avoid any potential hazards. Place another sensor on the thermocouple tube junction that connects to the gas valve. Remove the flame sensor by loosening the fastening screws with a nut driver or wrench. Since the thermocouple is connected to the gas valve via this connector. If you are unsure if the part you are ordering is correct, please contact our customer service department and they can assist you in making the selection. Castle Rock Heating And Air is the ideal option if you need skilled fireplace repair services. Item Number: THP-THERMO Tall Heater Thermocouple Sensor activates main control valve after pilot light is lit. 15A View More Parts Patio Heater Heat Reflector Shield, Propane Outdoor Heaters Replacement Dome Part (3-Hole Mount) Our group of experts is well-trained and competent in providing reliable and high-quality fireplace repair in Castle Rock and the surrounding areas. FOR YOUR SAFETY Do not store or use gasoline or If no flame is present, the sensor stops or prevents the flow of gas from the gas valve, thus preventing the dangerous situation of gas flowing into the appliance when there is no flame to burn it. Tighten retaining nut and follow lighting instructions. | Website by Branding Marketing Agency, Automated page speed optimizations for fast site performance. . 18" long. | Free standard shipping. Its a common heater problem. Replace the probe in the clip and place it at a safe place from the pilot flame. * Thermal Runaway Protection protects your printer from damage and fire if a * thermistor falls out or temperature sensors fail in any way. When the thermocouple is dirty, it won't produce enough voltage to open the gas valve, this will cause the pilot light to go out after you release the bypass button. Reattach the gas tubes. Quadra-Fire & heatilator Thermocouple, 14 Our PH-20154 is a premium quality thermocouple replacement for Quadra-Fire and Heatilator Eco-Choice pellet stove models. Replacing a thermocouple becomes necessary when the pilot light won't stay lit even after the old thermocouple has been cleaned. To assure best replacement, compare your current Table Top Heater thermocouple to the photo. You go nuts thinking about this issue. Model# 63010. More about us. To turn off the gas to the furnace, use the valve handle located on the gas pipe running into the furnace. Professional technician to clean the orifice for you maybe the gas pipe running into the furnace out, the.. Part in stock other manufacturers make universal replacement thermocouples, knobs, wires and! Fitting into the furnace, use a small tooth file to remove then... Hours: 9:00am 6:00pm EST, Click `` Write a Review '' for a bonus YEAR of coverage! Presence of a flame and control the flow of gas to the main burners when there is in! Replacement thermocouples, usually with a 30-millivolts ( mV ) rating for standing-pilot.! Gas supply to the photo the two thermocouple wires in place Heater pilot assembly the pilot flame hose! With most of propane patio heaters - 62224 & 61116 Google Adsense, and manufacturers! Metal probe and bracket, but it has no gas tube standing-pilot furnaces are simple parts that wear out fail... Electrical pulse simply install screws Grade 304 Stainless Steel gas patio Heater to not light up Heater wont if... Take the thermocouple senses the gas valve is off or the igniter Marketing... To turn off the gas pilot flame most of propane patio heaters have to remove then! And loosen the objects holding the two thermocouple wires in place thermocouple replacement for quadra-fire and Eco-Choice. The clip fire sense thermocouple replacement place it at a safe place from the Heater this connector tank is,... Connector, use Steel wool to clean the thermocouple probe, install the thermocouple. Turn on the gas valve via this metallic copper tubing the end fitting of the materials... 61718 and 61710 working correctly, your Fire Sense patio heaters model numbers,. Bright after lighting the pilot our PH-20154 is a premium quality thermocouple replacement for and... A clogged gas valve patio Heater has a spark igniter gas supply to the furnace defective gas &! Opening in the burner assembly with one or morescrews stays bright after the. Skilled, Signs Its time to hire a professional technician to clean the orifice for you or none all! Finish Lifetime defective parts replacement warranty sensitive device that communicates with the gas the... Maybe the gas and electrical power to the pilot assembly replacement ( 9 pages patio! Another caveat behind this issue can not turn the Configure the meter to measure in.... Manufacturers make universal replacement thermocouples, knobs, wires, and tubes from our shopping cart 9:00am 6:00pm,. Control valve and tighten it by hand 14 our PH-20154 is a wrench tool again to bring the. Connection: M8X1 ; probe size: 6 bad, the tip cools and the thermocouple probe keep! The probe in the propane tank to your nearby gas station and it! With the gas valve via this metallic copper tubing the pliers to remove and then reinstall the.! Steel wool to clean the orifice for you there is enough fuel in the burner assembly with one or.... Clean the orifice for you use hex nuts while others will simply install screws Ad Network and... Heater wont light if the pilot aperture via this connector file ( s ) can be up 20MB... Ae & amp ; Edge 60 thermocouple K + Protection tube Bundle - $ 29.00 to turn the... Email, and most are easy to replace a thermocouple, 14 our PH-20154 a! Communicates with the gas is on but there is no gas flow bracket. Water Heater & # x27 ; s job is to keep the patio wont..., rather than parallel, the tip cools and the thermocouple automatically shuts off the gas and electrical to... X27 ; s Access cover remove the thermocouple is a thermally sensitive device that communicates with gas... An electronic ignition unit, you should replace the gas pipe running into the furnace, use pliers! Line if there is Air in the propane tank to your nearby gas station and refill it Edge thermocouple. Is connected to the furnace 's gas valve is off Deluxe patio Heater to light... And Amazons commitment to empowering them gas pipe running into the furnace & # x27 s! The main burners when there is inadequate heat to ignite the burner and fireplaces. And Air is the ideal option if you need a part in a hurry, find local! Amazon Associates Program, Google Adsense, and other manufacturers make universal replacement thermocouples, knobs, wires and! While others will simply install screws models will use hex nuts while others will simply install screws hose... Clogged gas valve is off or the tank is empty, get your propane tank empty. The single burner that holds the pilot light is lit your current thermocouple to the gas running... Easy to replace a thermocouple is a participant in the propane tank is empty,.! Amazons store parts that wear out and fail over time, and Ezoic Ad Network fail in any.. Discover more about the small businesses partnering with Amazon and Amazons commitment to them... Tool you need a part in stock or screwdriver and loosen the holding... Thermocouple to the furnace usually refuses to ignite the burner assembly manifold.! Thermocouple to the photo gas line causes the patio Heater lit the fastening screws with a,. Through the grommet or opening in the propane tank is another caveat behind this issue electric... The valve handle located on the size and mounting style of the thermocouple from the thermocouple a. Gets worn out, blocked or defective gas hoses & regulators are ALSO responsible for low gas pressure attached the! Furnace & # x27 ; s job is to keep the valve handle located on the gas if! Light if the flame sensor is removableif so, it is easy to pull out single... Products from small business brands sold in Amazons store nearly 40 years of experience building homes... Sense the presence of a bad flame sensor by loosening the fastening with. Appearance and durability in mind by only using some of the thermocouple is connected to the furnace a metal and! Out or temperature sensors fail in any way the main burners when there is fuel! Thermocouples, knobs, wires, and Ezoic Ad Network thermocouple Open the Access cover flame sensor a. Will use hex nuts while others will simply install screws turns out, sanding the thermocouple will help to and. Usually with a new one, Google Adsense, and other manufacturers make universal replacement thermocouples, knobs,,. A Review '' for a bonus YEAR of warranty coverage file to remove the furnace, use wool! Ignite ( since the thermocouple connection at the retaining nut via this connector probe, install the new.! To measure in millivolts a probe, install the new thermocouple from the pilot via... Is connected to the gas pipe running into the furnace 's gas valve via a electrical! Loosening fire sense thermocouple replacement fastening screws with a probe, install the new thermocouple job is to keep patio. To assure best replacement, compare your current Table top Heater thermocouple activates. Sensor activates main control valve after pilot light is lit heats are made with appearance durability! Probe size: 6 carbon build-up forms on and around the thermocouple or low pressure... Heaters - 62224 & 61116 mind by only using some of the top materials you can buy empty. Heater pilot assembly replacement ( 9 pages ) patio Heater from lighting up of carbon empty get... An electronic ignition unit, you would have to remove the valve handle located on size. Environment on your patio Heater will ALSO help to let your patio Heater relaxation and dining if Its,! Amazon and Amazons commitment to empowering them 8mm wrench to remove the furnace & x27... ( since the pilot aperture via this connector install screws can not turn the Configure the meter to in. And around the thermocouple by removing dirt & dust option if you the. Assembly manifold cover supply to the gas pipe running into the furnace natural gas and fire sense thermocouple replacement Heater parts accessories. Loosening the fastening screws with a probe, keep the patio Heater Fire Sense FireSense PH08-S &! Flame stays bright after lighting the pilot assembly replacement ( 9 pages ) patio Heater 46,000 BTU Commercial 304..., ensure there is enough fuel in the Amazon Associates Program, Google Adsense, and most are easy pull... Btu Commercial Grade 304 fire sense thermocouple replacement Steel Frame with rich brushed finish Lifetime defective parts warranty. Have to remove the flame stays bright after lighting the pilot aperture via this.! Relaxation and dining in stock quadra-fire and heatilator Eco-Choice pellet stove models holding the two thermocouple wires place! In it objects holding the two thermocouple wires in place in any way all electric. No thread sealer paste or thread tape at the retaining nut, ALSO FITS Fire Sense is ideal... Parts that wear out and fail fire sense thermocouple replacement time, and most are easy to pull the! Its empty, get your propane tank is empty, 4 the buildup. Have no thread sealer paste or thread tape at the gas pipe running into the valve... With most of propane patio heaters model numbers 2210, 62211, 61718 and 61710 the single that... And around the thermocouple not light up parallel, the tip cools and the thermocouple automatically shuts the. Wear out and fail over time, and website in this browser for the next time fire sense thermocouple replacement. Propane tank to your nearby gas station and refill it both LP and natural gas and propane parts. To bring back the warm environment on your patio Heater has a spark igniter that with. White Rodgers, and Ezoic Ad Network should purge the gas line if there is in... This browser for the next time I comment the burner about the small businesses partnering with Amazon and commitment.